Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Int Arch Otorhinolaryngol ; 27(4): e636-e644, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37876687

RESUMO

Introduction The number of stimuli is important to determine the quality of auditory evoked potential records. However, there is no consensus on that number in studies, especially in the sample studied. Objectives To investigate the influence of the number of rare stimuli on forming N2 and P3 components, with different types of acoustic stimuli. Methods Cross-sectional, descriptive, comparative study, approved by the ethics committee of the institution. The sample comprised 20 normal hearing adults of both sexes, aged 18 to 29 years old, with normal scores in the mental state examination and auditory processing skills. The event-related auditory evoked potentials were performed with nonverbal (1 kHz versus 2 kHz) and verbal stimuli (/BA/ versus /DA/). The number of rare stimuli varied randomly in the recordings, with 10, 20, 30, 40, and 50 presentations. Results P3 latency was significantly higher for nonverbal stimuli with 50 rare stimuli. N2 latency did not show any difference between the type and number of stimuli. The absolute P3 and N2-P3 amplitudes showed significant differences for both types of stimuli, with higher amplitude for 10 rare stimuli, in contrast with the other ones. The linear tendency test indicated significance only for the amplitude - as the number of rare stimuli increased, the amplitude tended to decrease. Conclusion The components were identifiable in the different numbers of rare stimuli and types of stimuli. The P3 and N2-P3 latency and amplitude increased with fewer verbal and nonverbal stimuli. Recording protocols must consider the number of rare stimuli.

2.
Braz. j. otorhinolaryngol. (Impr.) ; 89(5): 101303, Sept.-Oct. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520495

RESUMO

Abstract Objectives: To review and provide evidence-based recommendations for the diagnosis and treatment of otosclerosis. Methods: Task force members were educated on knowledge synthesis methods, including electronic database search, review and selection of relevant citations, and critical appraisal of selected studies. Articles written in English or Portuguese on otosclerosis were eligible for inclusion. The American College of Physicians' guideline grading system and the American Thyroid Association's guideline criteria were used for critical appraisal of evidence and recommendations for therapeutic interventions. Results: The topics were divided into 2 parts: 1) Diagnosis - audiologic and radiologic; 2) Treatment - hearing AIDS, pharmacological therapy, stapes surgery, and implantable devices - bone-anchored devices, active middle ear implants, and Cochlear Implants (CI). Conclusions: The pathophysiology of otosclerosis has not yet been fully elucidated, but environmental factors and unidentified genes are likely to play a significant role in it. Women with otosclerosis are not at increased risk of worsening clinical condition due to the use of contraceptives or during pregnancy. Drug treatment has shown little benefit. If the patient does not want to undergo stapedotomy, the use of hearing aids is well indicated. Implantable systems should be indicated only in rare cases, and the CI should be indicated in cases of profound deafness.

3.
Int. arch. otorhinolaryngol. (Impr.) ; 27(3): 518-527, Jul.-Sept. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1514242

RESUMO

Abstract Introduction The P300 auditory evoked potential is a long-latency cortical potential evoked with auditory stimulation, which provides information on neural mechanisms underlying the central auditory processing. Objectives To identify and gather scientific evidence regarding the P300 in adult cochlear implant (CI) users. Data Synthesis A total of 87 articles, 20 of which were selected for this study, were identified and exported to the Rayyan search software. Those 20 articles did not propose a homogeneous methodology, which made comparison more difficult. Most articles (60%) in this review compare CI users with typical hearing people, showing prolonged P300 latency in CI users. Among the studies, 35% show that CI users present a smaller P300 amplitude. Another variable is the influence of the kind of stimulus used to elicit P300, which was prolonged in 30% of the studies that used pure tone stimuli, 10% of the studies that used pure tone and speech stimuli, and 60% of the studies that used speech stimuli. Conclusion This review has contributed with evidence that shows the importance of applying a controlled P300 protocol to diagnose and monitor CI users. Regardless of the stimuli used to elicit P300, we noticed a pattern in the increase in latency and decrease in amplitude in CI users. The user's experience with the CI speech processor over time and the speech test results seem to be related to the P300 latency and amplitude measurements.

4.
Int Arch Otorhinolaryngol ; 27(3): e518-e527, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37564465

RESUMO

Introduction The P300 auditory evoked potential is a long-latency cortical potential evoked with auditory stimulation, which provides information on neural mechanisms underlying the central auditory processing. Objectives To identify and gather scientific evidence regarding the P300 in adult cochlear implant (CI) users. Data Synthesis A total of 87 articles, 20 of which were selected for this study, were identified and exported to the Rayyan search software. Those 20 articles did not propose a homogeneous methodology, which made comparison more difficult. Most articles (60%) in this review compare CI users with typical hearing people, showing prolonged P300 latency in CI users. Among the studies, 35% show that CI users present a smaller P300 amplitude. Another variable is the influence of the kind of stimulus used to elicit P300, which was prolonged in 30% of the studies that used pure tone stimuli, 10% of the studies that used pure tone and speech stimuli, and 60% of the studies that used speech stimuli. Conclusion This review has contributed with evidence that shows the importance of applying a controlled P300 protocol to diagnose and monitor CI users. Regardless of the stimuli used to elicit P300, we noticed a pattern in the increase in latency and decrease in amplitude in CI users. The user's experience with the CI speech processor over time and the speech test results seem to be related to the P300 latency and amplitude measurements.

5.
Braz J Otorhinolaryngol ; 89(5): 101303, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37647735

RESUMO

OBJECTIVES: To review and provide evidence-based recommendations for the diagnosis and treatment of otosclerosis. METHODS: Task force members were educated on knowledge synthesis methods, including electronic database search, review and selection of relevant citations, and critical appraisal of selected studies. Articles written in English or Portuguese on otosclerosis were eligible for inclusion. The American College of Physicians' guideline grading system and the American Thyroid Association's guideline criteria were used for critical appraisal of evidence and recommendations for therapeutic interventions. RESULTS: The topics were divided into 2 parts: 1) Diagnosis - audiologic and radiologic; 2) Treatment - hearing AIDS, pharmacological therapy, stapes surgery, and implantable devices - bone-anchored devices, active middle ear implants, and Cochlear Implants (CI). CONCLUSIONS: The pathophysiology of otosclerosis has not yet been fully elucidated, but environmental factors and unidentified genes are likely to play a significant role in it. Women with otosclerosis are not at increased risk of worsening clinical condition due to the use of contraceptives or during pregnancy. Drug treatment has shown little benefit. If the patient does not want to undergo stapedotomy, the use of hearing aids is well indicated. Implantable systems should be indicated only in rare cases, and the CI should be indicated in cases of profound deafness.


Assuntos
Implante Coclear , Implantes Cocleares , Otosclerose , Cirurgia do Estribo , Humanos , Feminino , Otosclerose/terapia , Otosclerose/cirurgia , Brasil , Cirurgia do Estribo/métodos
7.
Braz J Otorhinolaryngol ; 89(1): 190-206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36528468

RESUMO

OBJECTIVES: To provide an overview of the main evidence-based recommendations for the diagnosis of hearing loss in children and adolescents aged 0-18 years. METHODS: Task force members were educated on knowledge synthesis methods, including electronic database search, review and selection of relevant citations, and critical appraisal of selected studies. Articles written in English or Portuguese on childhood hearing loss were eligible for inclusion. The American College of Physicians' guideline grading system and the American Thyroid Association's guideline criteria were used for critical appraisal of evidence and recommendations for therapeutic interventions. RESULTS: The topics were divided into 2 parts: (1) treatment of sensorineural hearing loss: individual hearing aids, bilateral cochlear implants, cochlear implants in young children, unilateral hearing loss, and auditory neuropathy spectrum disorder; and (2) treatment of conductive/mixed hearing loss: external/middle ear malformations, ventilation tube insertion, and tympanoplasty in children. CONCLUSIONS: In children with hearing loss, in addition to speech therapy, Hearing AIDS (HAs) or implantable systems may be indicated. Even in children with profound hearing loss, both the use of HAs and behavioral assessments while using the device are important.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adolescente , Criança , Humanos , Pré-Escolar , Brasil , Perda Auditiva/terapia , Perda Auditiva/cirurgia , Surdez/cirurgia , Perda Auditiva Neurossensorial/terapia
8.
Dev Neurosci ; 45(1): 27-36, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36580902

RESUMO

The aim of the study was to investigate three aspects of auditory function (auditory acuity, cochlear dysfunction, and auditory processing) in adolescents with fetal alcohol exposure without phenotypic changes. Fifty-one adolescents with and without intrauterine exposure to alcohol were selected from a cohort study. The summons, evaluation, and analysis of the results were carried out blindly regarding the respective exposure to alcohol. The auditory tests were pure-tone audiometry, transient otoacoustic emissions, and behavioral assessment of auditory processing (speech-in-noise, dichotic digits, and gap-in-noise). After testing, 45 adolescents were included in the evaluation and were divided into exposed (n = 22) and non-exposed (n = 23) groups. Hearing loss was identified in one subject in the exposed group (4.5%). In the absence of hearing loss, there were no significant differences in tonal thresholds or in the magnitudes of the sensory (cochlear) responses between groups (p > 0.05). There was also no difference between the two groups regarding performance on the processing tests (speech-in-noise p = 0.71, dichotic p = 0.94, and gap-in-noise p = 0.33). However, the exposed group had more cases of hearing disorders (hearing loss plus auditory processing disorders) than the non-exposed group (22.7% vs. 4.3%).


Assuntos
Perda Auditiva , Efeitos Tardios da Exposição Pré-Natal , Gravidez , Humanos , Feminino , Adolescente , Estudos de Coortes , Ruído , Audiometria de Tons Puros
9.
Braz J Otorhinolaryngol ; 89(1): 159-189, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36529647

RESUMO

OBJECTIVES: To provide an overview of the main evidence-based recommendations for the diagnosis of hearing loss in children and adolescents aged 0 to 18 years. METHODS: Task force members were educated on knowledge synthesis methods, including electronic database search, review and selection of relevant citations, and critical appraisal of selected studies. Articles written in English or Portuguese on childhood hearing loss were eligible for inclusion. The American College of Physicians' guideline grading system and the American Thyroid Association's guideline criteria were used for critical appraisal of evidence and recommendations for therapeutic interventions. RESULTS: The evaluation and diagnosis of hearing loss: universal newborn hearing screening, laboratory testing, congenital infections (especially cytomegalovirus), genetic testing and main syndromes, radiologic imaging studies, vestibular assessment of children with hearing loss, auditory neuropathy spectrum disorder, autism spectrum disorder, and noise-induced hearing loss. CONCLUSIONS: Every child with suspected hearing loss has the right to diagnosis and appropriate treatment if necessary. This task force considers 5 essential rights: (1) Otolaryngologist consultation; (2) Speech assessment and therapy; (3) Diagnostic tests; (4) Treatment; (5) Ophthalmologist consultation.


Assuntos
Transtorno do Espectro Autista , Surdez , Perda Auditiva , Otolaringologia , Recém-Nascido , Adolescente , Criança , Humanos , Estados Unidos , Brasil , Perda Auditiva/diagnóstico
10.
Int. arch. otorhinolaryngol. (Impr.) ; 27(4): 636-644, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528717

RESUMO

Abstract Introduction The number of stimuli is important to determine the quality of auditory evoked potential records. However, there is no consensus on that number in studies, especially in the sample studied. Objectives To investigate the influence of the number of rare stimuli on forming N2 and P3 components, with different types of acoustic stimuli. Methods Cross-sectional, descriptive, comparative study, approved by the ethics committee of the institution. The sample comprised 20 normal hearing adults of both sexes, aged 18 to 29 years old, with normal scores in the mental state examination and auditory processing skills. The event-related auditory evoked potentials were performed with nonverbal (1 kHz versus 2 kHz) and verbal stimuli (/BA/ versus /DA/). The number of rare stimuli varied randomly in the recordings, with 10, 20, 30, 40, and 50 presentations. Results P3 latency was significantly higher for nonverbal stimuli with 50 rare stimuli. N2 latency did not show any difference between the type and number of stimuli. The absolute P3 and N2-P3 amplitudes showed significant differences for both types of stimuli, with higher amplitude for 10 rare stimuli, in contrast with the other ones. The linear tendency test indicated significance only for the amplitude - as the number of rare stimuli increased, the amplitude tended to decrease. Conclusion The components were identifiable in the different numbers of rare stimuli and types of stimuli. The P3 and N2-P3 latency and amplitude increased with fewer verbal and nonverbal stimuli. Recording protocols must consider the number of rare stimuli.

11.
Braz. j. otorhinolaryngol. (Impr.) ; 89(1): 190-206, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420924

RESUMO

Abstract Objectives: To provide an overview of the main evidence-based recommendations for the diagnosis of hearing loss in children and adolescents aged 0-18 years. Methods: Task force members were educated on knowledge synthesis methods, including electronic database search, review and selection of relevant citations, and critical appraisal of selected studies. Articles written in English or Portuguese on childhood hearing loss were eligible for inclusion. The American College of Physicians' guideline grading system and the American Thyroid Association's guideline criteria were used for critical appraisal of evidence and recommendations for therapeutic interventions. Results: The topics were divided into 2 parts: (1) treatment of sensorineural hearing loss: individual hearing aids, bilateral cochlear implants, cochlear implants in young children, unilateral hearing loss, and auditory neuropathy spectrum disorder; and (2) treatment of conductive/mixed hearing loss: external/middle ear malformations, ventilation tube insertion, and tympanoplasty in children. Conclusions: In children with hearing loss, in addition to speech therapy, Hearing AIDS (HAs) or implantable systems may be indicated. Even in children with profound hearing loss, both the use of HAs and behavioral assessments while using the device are important.

12.
Childs Nerv Syst ; 38(2): 269-277, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34698910

RESUMO

PURPOSE: The jugular and tympanic glomus are rare neoplasms in the general population, being even more uncommon in the pediatric population. There is considerable morbidity associated with both disease and treatment. Treatment is essentially surgical, carried out in recent years in a multidisciplinary manner using preoperative embolization associated with microsurgery and eventually adjuvant radiotherapy. The outcome depends on the location of the lesion and its proximity to noble structures in addition to multidisciplinary monitoring in the postoperative period. METHODS: In this article, a literature review was carried out in the PubMed database, finding reports from 17 patients diagnosed with the disease. Only articles in English were considered. RESULTS: Moreover, we reported a case of a 14-year-old patient diagnosed with jugulotympanic glomus who underwent radical surgical treatment of the lesion. CONCLUSION: This is a rare case of jugulotympanic glomus in a pediatric patient, who underwent surgical treatment associated with multidisciplinary therapy, with a favorable postoperative outcome.


Assuntos
Embolização Terapêutica , Tumor do Glomo Jugular , Glomo Jugular , Adolescente , Criança , Glomo Jugular/patologia , Tumor do Glomo Jugular/complicações , Tumor do Glomo Jugular/diagnóstico por imagem , Tumor do Glomo Jugular/cirurgia , Humanos
13.
Braz J Otorhinolaryngol ; 88 Suppl 1: S108-S117, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34034979

RESUMO

INTRODUCTION: Electrically evoked auditory brainstem responses provide reliable clinical information to assist professionals in the auditory rehabilitation of cochlear implant users. OBJECTIVE: This study aimed to investigate intraoperative evoked auditory brainstem response recordings in Evo®-cochlear implant electrode array recipients and its correlation with their behavioral levels and auditory performance. METHODS: This is a retrospectivey study. Intraoperative evoked auditory brainstem responses were recorded in adult Evo®-cochlear implant electrode array recipients. Wave V latencies, amplitudes and interpeak III-V intervals were recorded in three different electrode locations and compared to the sentence recognition scores obtained from subjects after six months of device use. Evoked auditory brainstem responses thresholds were also recorded and compared to the behaviorally determined levels of the subjects in the sound processor activation. RESULTS: Evoked auditory brainstem responses thresholds were significantly correlated with both, behavioral T- and C-levels and they were recorded at audible electrical stimulation levels in all subjects. There was a significant correlation between interpeak III-V interval recorded in the apical electrode and sentence recognition scores of the subjects. CONCLUSIONS: Intraoperative evoked auditory brainstem responses can be used to establish audible levels for fitting the sound processor in Evo®-cochlear implant recipients and it could help professionals to plan further actions aiming to improve their auditory performance.

14.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.1): 108-117, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420796

RESUMO

Abstract Introduction Electrically evoked auditory brainstem responses provide reliable clinical information to assist professionals in the auditory rehabilitation of cochlear implant users. Objective This study aimed to investigate intraoperative evoked auditory brainstem response recordings in Evo®-cochlear implant electrode array recipients and its correlation with their behavioral levels and auditory performance. Methods This is a retrospectivey study. Intraoperative evoked auditory brainstem responses were recorded in adult Evo®-cochlear implant electrode array recipients. Wave V latencies, amplitudes and interpeak III-V intervals were recorded in three different electrode locations and compared to the sentence recognition scores obtained from subjects after six months of device use. Evoked auditory brainstem responses thresholds were also recorded and compared to the behaviorally determined levels of the subjects in the sound processor activation. Results Evoked auditory brainstem responses thresholds were significantly correlated with both, behavioral T- and C-levels and they were recorded at audible electrical stimulation levels in all subjects. There was a significant correlation between interpeak III-V interval recorded in the apical electrode and sentence recognition scores of the subjects. Conclusions Intraoperative evoked auditory brainstem responses can be used to establish audible levels for fitting the sound processor in Evo®-cochlear implant recipients and it could help professionals to plan further actions aiming to improve their auditory performance.


Resumo Introdução Os potenciais auditivos de tronco encefálico evocados eletricamente fornecem informações clínicas confiáveis que auxiliam no processo de reabilitação auditiva de usuários de implante coclear. Objetivo Investigar o registro intraoperatório dos potenciais auditivos de tronco encefálico evocados eletricamente em usuários do feixe de eletrodos Evo® e sua correlação com os níveis comportamentais e desempenho auditivo dos indivíduos. Método Estudo retrospectivo. Os potenciais auditivos de tronco encefálico intraoperatórios foram registrados em usuários adultos de implante coclear com feixe de eletrodos Evo®. As latências e amplitudes da onda V e os intervalos interpico III-V foram registrados em três diferentes eletrodos e comparados às pontuações de reconhecimento de sentenças após 6 meses de uso do implante coclear. Os limiares dos eABRs foram comparados aos níveis comportamentais dos indivíduos na ativação do processador de som. Resultados Os limiares do eABR foram significativamente correlacionados aos níveis comportamentais T e C e registrados em níveis de estimulação elétrica audíveis em todos os indivíduos. Houve uma correlação significativa entre o intervalo interpico III-V no eletrodo apical e a pontuação de reconhecimento de sentenças dos indivíduos. Conclusões O eABR intraoperatório pode ser usado para estabelecer níveis audíveis de estimulação elétrica na ativação do processador sonoro em usuários de implante coclear‐Evo® e pode auxiliar os profissionais no planejamento de ações visando melhorar o desempenho auditivo nesses pacientes.

15.
Surg Neurol Int ; 12: 482, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34754532

RESUMO

BACKGROUND: Jugular foramen paragangliomas (JFP) treatment represents a challenge for surgeons due to its close relationship with facial nerve (FN), lower cranial nerves (LCN), and internal carotid artery. Due to its hypervascularization, preoperative tumor embolization has been indicated. METHODS: Retrospective analysis of the clinical evolution of 26 patients with JFP class C/D previously embolized treated through infratemporal/cervical access without FN transposition. RESULTS: Total and subtotal resections were 50% each, regrowth/recurrence were 25%, and 23%, respectively, and mortality was 3.9%. Postoperatively, 68.4% of patients had FN House and Brackmann (HB) Grades I/II. New FN deficits were 15.4% post embolization and 30.7% postoperatively. Previous FN deficits worsened in 46.1%. Tumor involved the FN in 30.8% and in 62.5% of them these nerves were resected and grafted (60% of them had HB III). Lateral fall, ear murmur, and vertigo improved in all patients. Tinnitus improved in 77.8% and one patient developed tinnitus after surgery. Hearing loss did not improve, eight partial hearing loss remained unchanged and four worsened. New postoperative LCN deficits were 64.3%. Postoperative KPS between 80 and 100 dropped 8.3%. Two patients with secretory paragangliomas with arterial hypertension difficult to control had better postoperative blood pressure control. CONCLUSION: Although still with significant morbidity due to FN and LCN injuries, the treatment of patients with JFP Fisch C/D has good long-term results. Surgical techniques without FN transposition have less intraoperative nerve damage, lower rates of total resection, and higher recurrence. Preoperative embolization of JFP reduces the intraoperative blood loss but can cause FN deficit.

16.
Int Arch Otorhinolaryngol ; 24(2): e191-e197, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32256840

RESUMO

Introduction Tinnitus, which is considered the third worst symptom for humans, is a common complaint among people living with hearing loss and may negatively affect the quality of life of those who have it. Objective To analyze the perception of the handicap in patients with tinnitus and hearing loss as well as the possible associations between the variables hearing loss, loudness, onset, frequency and annoyance by tinnitus, and the correlation between the visual analogue scale (VAS) and the Tinnitus Handicap Inventory (THI). Methods A total of 30 patients with complaints of tinnitus and the presence of sensorineural hearing impairment were selected for this cross-sectional, observational, and descriptive study. The loudness of the tinnitus was measured by a VAS and classified as mild, moderate, or severe. The THI was classified as slight, mild, moderate, severe, and catastrophic. Data were submitted to statistical analysis using the Fisher exact test and Spearman correlation coefficient. Results Eleven male (36.7%) and 19 female (63.3%) subjects with a mean age of 56.5 years old were evaluated. There was no significant association between loudness, annoyance, time and frequency of tinnitus, nor between hearing loss and tinnitus. There was a significant association between the variables hearing loss and loudness, and a weak correlation between VAS and THI. Conclusion Tinnitus has a practical impact in the lives of patients with hearing loss in terms of catastrophic, functional, and emotional aspects, regardless of loudness, frequency, or time of onset. Hearing loss was a factor that had an impact on the loudness of tinnitus. There was no statistically significant correlation between VAS and THI.

17.
Braz. j. otorhinolaryngol. (Impr.) ; 86(1): 3-13, Jan.-Feb. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1089375

RESUMO

Abstract Introduction Patient-reported outcome measures, inventory and or questionnaire, allow patients to present their perspective of the impact of their individual condition on a day-to-day basis, independent of the analysis of test results by the expert clinician. Outcome measures are recommended when there is evidence showing their reliability, validity and sensitivity. There are standardized patient-reported outcome measures for hearing in English language; however, other languages lack these instruments. Objective Adapt the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese and analyze its validation measures. Methods We conducted two studies. In Study 1, we translated and adapted the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese according to good practice guidelines; this included the pre-test stage. In Study 2, we administered the Portuguese version to adults with and without hearing loss (n = 31 and 18, respectively) and analyzed the measures of instrument validation, reliability, and reproducibility. Moreover, we calculated the correlation between pure tone thresholds and scores on the questionnaire. Results The results obtained in Study 1 demonstrated the feasibility of the translation process and the instrument's cultural adaptation, as well as its applicability, resulting in the Portuguese version of the Amsterdam inventory for auditory disability and handicap. In Study 2, the results revealed construct values for the questions and domains, as well as for the total reliable score. The intra-interviewer test-retest condition showed excellent reproducibility (ICC = 0.97). Finally, there was a strong positive correlation (r = 0.83) between the mean pure tone threshold and the hearing difficulties values, as measured by the instrument's scores. Conclusion The English version of the Amsterdam inventory for auditory disability and handicap could be translated and adapted to Brazilian Portuguese. An analyses of the validation process yielded reliable, consistent, and stable results.


Resumo Introdução Medidas de resultados relatados pelo paciente, inventários e/ou questionários, permitem que os pacientes apresentem suas perspectivas do impacto de sua condição no dia a dia, independentemente da análise dos resultados dos testes realizados pelo especialista. Esses instrumentos são recomendados quando há evidências que mostram sua confiabilidade, validade e sensibilidade. Existem medidas de resultados relatados pelo paciente padronizadas para a audição em língua inglesa; no entanto, esses instrumentos não existem em outras línguas. Objetivo Adaptar o Amsterdam inventory for auditory disability and handicap para o português brasileiro e avaliar suas medidas de validação. Método Realizamos dois estudos. No estudo 1, traduzimos e adaptamos o Amsterdam inventory for auditory disability and handicap para o português brasileiro de acordo com as diretrizes de boas práticas; inclusive a fase de pré-teste. No estudo 2, aplicamos a versão em português em adultos com e sem perda auditiva (n = 31 e 18, respectivamente) e analisamos as medidas de validação, confiabilidade e reprodutibilidade do instrumento. Além disso, calculamos a correlação entre os limiares de tons puros e os escores do questionário. Resultados Os resultados obtidos no estudo 1 demonstraram a viabilidade do processo de tradução e adaptação cultural do instrumento, assim como sua aplicabilidade, proporcionaram a versão em português da Amsterdam inventory for auditory disability and handicap. No estudo 2, os resultados revelaram valores de constructo para as questões e domínios, bem como para o escore total confiável. A condição de teste-reteste intraentrevistador mostrou excelente reprodutibilidade (CCI = 0,97). Por fim, houve forte correlação positiva (r = 0,83) entre o limiar médio de tom puro e os valores das dificuldades auditivas, medidos pelos escores do instrumento. Conclusão A versão em inglês do Amsterdam inventory for auditory disability and handicap foi traduzida e adaptada para o português brasileiro. Uma análise do processo de validação produziu resultados confiáveis, consistentes e estáveis.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Comparação Transcultural , Pessoas com Deficiência Auditiva , Avaliação da Deficiência , Perda Auditiva/diagnóstico , Psicometria , Percepção Auditiva , Limiar Auditivo , Tradução , Índice de Gravidade de Doença , Brasil , Estudos Transversais , Inquéritos e Questionários/normas , Reprodutibilidade dos Testes , Idioma
18.
Braz J Otorhinolaryngol ; 86(1): 3-13, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30224263

RESUMO

INTRODUCTION: Patient-reported outcome measures, inventory and or questionnaire, allow patients to present their perspective of the impact of their individual condition on a day-to-day basis, independent of the analysis of test results by the expert clinician. Outcome measures are recommended when there is evidence showing their reliability, validity and sensitivity. There are standardized patient-reported outcome measures for hearing in English language; however, other languages lack these instruments. OBJECTIVE: Adapt the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese and analyze its validation measures. METHODS: We conducted two studies. In Study 1, we translated and adapted the Amsterdam inventory for auditory disability and handicap to Brazilian Portuguese according to good practice guidelines; this included the pre-test stage. In Study 2, we administered the Portuguese version to adults with and without hearing loss (n=31 and 18, respectively) and analyzed the measures of instrument validation, reliability, and reproducibility. Moreover, we calculated the correlation between pure tone thresholds and scores on the questionnaire. RESULTS: The results obtained in Study 1 demonstrated the feasibility of the translation process and the instrument's cultural adaptation, as well as its applicability, resulting in the Portuguese version of the Amsterdam inventory for auditory disability and handicap. In Study 2, the results revealed construct values for the questions and domains, as well as for the total reliable score. The intra-interviewer test-retest condition showed excellent reproducibility (ICC=0.97). Finally, there was a strong positive correlation (r=0.83) between the mean pure tone threshold and the hearing difficulties values, as measured by the instrument's scores. CONCLUSION: The English version of the Amsterdam inventory for auditory disability and handicap could be translated and adapted to Brazilian Portuguese. An analyses of the validation process yielded reliable, consistent, and stable results.


Assuntos
Comparação Transcultural , Avaliação da Deficiência , Perda Auditiva/diagnóstico , Pessoas com Deficiência Auditiva , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Percepção Auditiva , Limiar Auditivo , Brasil , Estudos Transversais , Feminino , Humanos , Idioma , Masculino , Pessoa de Meia-Idade , Psicometria , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Inquéritos e Questionários/normas , Tradução , Adulto Jovem
19.
Int. arch. otorhinolaryngol. (Impr.) ; 20(4): 315-320, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828901

RESUMO

Abstract Introduction Hearing difficulties can be minimized by the use of hearing aids. Objective The objective of this study is to assess the speech perception and satisfaction of hearing aids users before and after aid adaptation and to determine whether these measures are correlated. Methods The study was conducted on 65 individuals, 54% females and 46% males aged 63 years on average, after the systematic use of hearing aids for at least three months. We characterized subjectś personal identification data, the degree, and configuration of hearing loss, as well as aspects related to adaptation. We then applied a satisfaction questionnaire and a speech perception test (words and sentences), with and without the use of the hearing aids. Results Mean speech recognition with words and sentences was 69% and 79 %, respectively, with hearing aids use; whereas, without hearing aids use the figures were 43% and 53%. Mean questionnaire score was 30.1 points. Regarding hearing loss characteristics, 78.5% of the subjects had a sensorineural loss, 20% a mixed loss, and 1.5% a conductive loss. Hearing loss of moderate degree was present in 60.5% of cases, loss of descending configuration in 47%, and plain loss in 37.5%. There was no correlation between individual satisfaction and the percentages of the speech perception tests applied. Conclusion Word and sentence recognition was significantly better with the use of the hearing aids. The users showed a high degree of satisfaction. In the present study, there was no correlation observed between the levels of speech perception and levels of user satisfaction measured with the questionnaire.

20.
Int Arch Otorhinolaryngol ; 20(4): 315-320, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27746833

RESUMO

Introduction Hearing difficulties can be minimized by the use of hearing aids. Objective The objective of this study is to assess the speech perception and satisfaction of hearing aids users before and after aid adaptation and to determine whether these measures are correlated. Methods The study was conducted on 65 individuals, 54% females and 46% males aged 63 years on average, after the systematic use of hearing aids for at least three months. We characterized subjects personal identification data, the degree, and configuration of hearing loss, as well as aspects related to adaptation. We then applied a satisfaction questionnaire and a speech perception test (words and sentences), with and without the use of the hearing aids. Results Mean speech recognition with words and sentences was 69% and 79%, respectively, with hearing aids use; whereas, without hearing aids use the figures were 43% and 53%. Mean questionnaire score was 30.1 points. Regarding hearing loss characteristics, 78.5% of the subjects had a sensorineural loss, 20% a mixed loss, and 1.5% a conductive loss. Hearing loss of moderate degree was present in 60.5% of cases, loss of descending configuration in 47%, and plain loss in 37.5%. There was no correlation between individual satisfaction and the percentages of the speech perception tests applied. Conclusion Word and sentence recognition was significantly better with the use of the hearing aids. The users showed a high degree of satisfaction. In the present study, there was no correlation observed between the levels of speech perception and levels of user satisfaction measured with the questionnaire.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...